Performance and Feature
√ Fully hermetic imported scroll or semi- hermetic piston compressor;
√ Electrical components and controlling components from world-renowned brand;
√ Set up multiple refrigeration circuits as system, and each circuit can be run independently;
√ Can precisely control all temperature in industrial production;
√ Stainless steel tank, automatic water replenishment and water level protection devices etc.;
√ Micro computer controller with LCD, Chinese/English Human-machine interface, operate easily and conveniently, complete control function;
√ Condenser and evaporator use imported seamless heat exchanging pipe with high heat exchanging efficiency and long useful life;
√ Can use R22 or environmentally friendlyR407C or R134a refrigerant.
Water Cooled Packaged/Scroll Chiller -15℃: BTXSYC-xxAS(D)(-15℃) |
Model |
3HP |
5HP |
8HP |
10HP |
12HP |
15HP |
20HP |
24HP |
25HP |
30HP |
40HP |
Cooling
Capacity |
KW |
3.6 |
5.5 |
8.6 |
13.1 |
14.9 |
16.7 |
26.1 |
29.7 |
29.6 |
33.4 |
47.5 |
104kcal/h |
0.3 |
0.5 |
0.7 |
1.1 |
1.3 |
1.4 |
2.2 |
2.6 |
2.5 |
2.9 |
3.8 |
Compressor |
Quantity |
1 |
1 |
1 |
1 |
1 |
1 |
2 |
2 |
1 |
2 |
2 |
Power |
2.03 |
3.02 |
4.85 |
6.11 |
6.89 |
9.56 |
12.22 |
13.78 |
16.10 |
19.12 |
25.10 |
Evaporator |
Pipe Size DN |
25 |
25 |
40 |
40 |
40 |
50 |
50 |
65 |
65 |
65 |
65 |
Flow Rate m3/h |
22.5 |
28.4 |
44.9 |
44.9 |
44.9 |
49.7 |
59.1 |
59.1 |
59.1 |
85.1 |
94.6 |
Condenser |
Pipe Size DN |
25 |
25 |
40 |
40 |
40 |
50 |
50 |
65 |
65 |
65 |
65 |
Flow Rate m3/h |
3.6 |
4.2 |
4.0 |
3.8 |
3.8 |
3.8 |
3.8 |
3.8 |
3.6 |
4.4 |
4.2 |
Water Pump |
Power KW |
0.37 |
0.55 |
1.1 |
1.1 |
1.1 |
1.5 |
1.5 |
2.2 |
2.2 |
2.2 |
2.2 |
Head m |
18 |
21 |
20 |
19 |
19 |
22 |
21 |
20 |
20 |
22 |
18 |
Water Tank |
Volume L |
85 |
90 |
190 |
190 |
190 |
210 |
250 |
250 |
250 |
360 |
400 |
Overall Size
(L:W:H) |
mm |
1350 |
1500 |
1350 |
1350 |
1350 |
1600 |
1900 |
1900 |
1900 |
2150 |
2300 |
mm |
850 |
850 |
850 |
850 |
850 |
1000 |
1000 |
1000 |
1000 |
1000 |
1200 |
mm |
1200 |
1200 |
1200 |
1200 |
1200 |
1200 |
1200 |
1200 |
1200 |
1200 |
1350 |
NOTE:
1.Normal Conditions: Chilled water inlet/outlet temperature-10℃/-15℃, and cooling water inlet/outlet temperature30℃/35℃;
2. Dirt coefficient 0.086m2℃/Kw,Cooling water side pressure1.0MPa;
3.Operating Condition:Chilled water inlet temperature-13-(-17)℃;
4. Input Power: 3P-380V-50Hz, allowable voltage fluctuation: ±10%, allowable voltage difference in phase: ±2%;
5. Actual head for overall unit= Head of water pump- Internal pressure drop loss of overall unit(1mH2O=9.8KPa);
6.Accept orders for special requirements.